BOILPLEX AT Hardness Control
In addition to controlling the alkali content, scale and sediment, Boilplex ATprotects the condensate system (Steam superheater) from corrosion caused by low pH. Boilplex AT control sludge and sediment deposition by adsorption on sludge boiler surfac
RXSOL BOILPLEX AT – Advanced Boiler Water Treatment Chemical
Phosphate–Polymer Boiler Treatment | Scale Inhibitor | Sludge Conditioner | Corrosion Control
Product Name: BOILPLEX AT Hardness Control
Product Code: RXSOL-40-5027-025
Brand: RXSOL
Category: Marine & Industrial Boiler Water Treatment
Reference Product: DREWPLEX AT by Drew Marine
RXSOL already lists BOILPLEX AT Hardness Control (RXSOL-40-5027-025) as its phosphate–polymer boiler treatment product for applications similar to DREWPLEX AT.
THINK RXMARINE
BOILPLEX AT Hardness Control is specialized Boiler Water treatment product to KEEP Boiler water Clear and Clean SLUDGE FREE.
Boilplex AT is basically phosphates combination with synthetic polymers. Very easy to use, provides flexibility in system operation and control over the operation of the auxiliary and exhaust gas heaters on the boats. The tool is designed to maintain the cleanliness of the boiler at unstable as feedwater.
Product details & specifications
Product Description
RXSOL BOILPLEX AT is a multipurpose boiler water treatment chemical based on a combination of phosphates, synthetic polymers, alkalinity-control agents and deposit-conditioning additives.
The product is designed to control hardness-related scale, sludge formation and corrosion in low- and medium-pressure marine and industrial boiler systems.
RXSOL BOILPLEX AT helps maintain boiler cleanliness by conditioning hardness precipitates and suspended impurities, preventing their firm adhesion to heat-transfer surfaces. Its polymeric dispersants assist in maintaining soft, mobile sludge that can be removed through routine boiler blowdown.
The treatment is particularly useful in boiler systems experiencing variations in feedwater quality, condensate return conditions and makeup water composition.
When used as part of a complete boiler treatment program with an appropriate oxygen scavenger, RXSOL BOILPLEX AT supports reliable boiler operation, improved heat-transfer performance and reduced deposit-related maintenance.
To be most effective to prevent corrosion and scaling using drug Boilplex AT the drug should be constantly adding to the boiler system with a dosing devices BWT Dosing System. Less preferable to use gravitational dosing device, because preparation can evaporate when the water returns into the tank cascade.
Recommended Dosage and Application
Initial Treatment
For reference, the original DREWPLEX AT manufacturer recommends an initial treatment of 2.5–5 litres per metric tonne of boiler system water. This is a reference-product dosage, not a verified RXSOL BOILPLEX AT dosage.
Actual RXSOL dosing should be determined from its active concentration, boiler water analysis, system volume and operating conditions.
Continuous Dosing Procedure
-
Determine the total boiler water volume and operating pressure.
-
Check feedwater quality, hardness, conductivity, pH and alkalinity.
-
Prepare the treatment solution using suitable clean condensate or demineralized water, where approved.
-
Dose continuously through a calibrated chemical dosing pump into the designated feedwater line.
-
Monitor boiler water alkalinity, phosphate, conductivity and condensate quality.
-
Adjust treatment dosage and blowdown according to the approved control program.
Regularly enter solutions drugs Boilplex AT with a dosing device BWT Dosing System in feedwater recirculation outlet below which returns cascading water in the tank. If there is no recirculation of feedwater, the drug should be submitted in suction tube feeding pump. When using gravity dispenser the drug should be fed to the point of feed water tank or in cascade. Drug supply line should be higher than normal water level (about 1 meter) and as close as possible to the fence of water nutrient pump. Boilplex AT to be dissolved in distilled water or condensate in the dispensing tank and gradually continuously fed for 24 hours, keeping the system demand. The daily dosage is depend on the volume of the system, the condensate quality and purity, as well as the quality and quantity of the feed water system. For standard operating systems the dosage Boilplex AT is about 1 liter a day.
Very large systems or in non-standard conditions will have a greater need for preparation. Many factors can affect the initial dose of the drug. The two most important factors - quality feedwater and the boiler. The recommended initial dose of 2.5 to 5 liters per tonne of water system. After the initial filling of the product during operation of the system on a daily basis should perform a test to adjust the dosage. Low quality feedwater demands increase quantities of preparation, as well as leaching of the polluted water from the boiler of the boiler due to the settling of particles on bottom of the boiler during system shutdown. This in turn entails the need for additional purging and increase the amount of drug.
The main objective of the program - to prevent fouling. The most effective way to fight c deposits is to use distilled water feed. Boilplex AT created for removing water hardness instability.
Blowdown
Purge procedure is necessary for the effectiveness of any treatment program and boiler watershall be in accordance recommendations manufacturer's instructions. Purging is required to remove the precipitate dissolved and suspended solids. Normal regular purging with sufficient neutral of conductivity 700 μmho. A higher rate of conductivity (above 700 μmho) frequency blowdown should be increased. Additionally, it is recommended to wash weekly collector or separator pair (if any) to reduce the accumulation of sludge.
|
Appearance |
: Clear liquid |
|
Specific gravity at 25 º C (77 º F) |
: 1.056 |
|
Fire |
: off |
|
Freezing temperature |
: -6.6 º C (20 º F) |
|
pH |
: 13.4 |
|
Stability after freeze / that |
: yes |
Testing:
Dosage and frequency Boilplex AT controlled blowdown simple tests on the quality of the boiler water.Tests include checking parameters such as hydrate alkalinity, conductivity, phosphates, stiffness feedwater and condensate pH. For more information about the testing procedure, refer to Table control the amount and dosage Boilplex AT Control and Dosage Chart or contact representative of Rx Marine International.
CHARACTERISTICS :
- Has dispersant properties.
- Converts crystals.
- Comprehensive protection.
- Air conditioning sludge.
- Multi-tool.
- Prevents scale.
- Easy to use and testing.
BENEFITS
- Do not allow the particles to stick together.
- Do not allow the build-up of scale on pipes.
- Provides efficient heat transfer.
- Soft sludge" can be easily removed by blowing.
- Redundant components ensure protection.
- Boiler Cleaner.
- Increases in operation.
- Reduces the need for acid peels.
- Saves maintenance costs Kotel.
- Control of corrosion caused due to low.
- pH levels in the condensate system.
- Controls alkalinity.
- Controls the formation of a new scale.
- Convenient for operator.
Did you know, how to keep BOILER water CLEAR and Sludge free?
RXSOL BOILPLEX AT Phosphate and synthetic polymer Based Boiler water treatment chemicals to control sludge for low and medium pressure Boilers which results in the clean boiler water. USES of RXSOL BOILPLEX AT Hardness Control provide tolerance of feedwater quality fluctuations.
Chemically one part of The polymers used in BOILPLEX AT keeping the sludge particles soft by increasing property of nonadherent which also resulting smooth blowdown during boiler cleaning and maintenance operation.
While Other part of Phosphate which is used in BOILPLEX AT serve as deposit control agents by Iron dispersancy, main cause of sequestering deposits.
USES of RXSOL BOILPLEX AT boiler water treatment, can help BOILER WATER CLEAN and CLEAR.
Frequently Asked Questions
Q1. What is RXSOL BOILPLEX AT used for?
It is a multipurpose boiler water treatment chemical designed for hardness control, scale prevention, sludge conditioning and alkalinity management.
Q2. Is RXSOL BOILPLEX AT an alternative to DREWPLEX AT?
RXSOL markets BOILPLEX AT for a similar phosphate–polymer boiler treatment application. Direct equivalence requires comparative formulation and performance testing.
Q3. Can BOILPLEX AT be used in marine auxiliary boilers?
Yes, subject to the boiler manufacturer's recommendations, operating pressure and verified RXSOL treatment specifications.
Q4. Does BOILPLEX AT prevent boiler scale?
Its phosphate and polymer treatment approach is intended to reduce hardness-related deposits and help prevent adherent scale.
Q5. Does BOILPLEX AT contain an oxygen scavenger?
Oxygen-scavenging performance has not been established for this RXSOL formulation. A separate approved oxygen scavenger should be used when required.
Q6. What is the recommended dosage?
Dosage depends on the actual product concentration, boiler volume, makeup water quality and boiler water test results. The reference DREWPLEX AT initial dosage is 2.5–5 L/tonne, but this must not be automatically transferred to RXSOL.
Q7. Can BOILPLEX AT be used in food-processing boilers?
Only if the actual RXSOL formulation has the necessary approvals for the intended steam-contact application. The NSF registrations of DREWPLEX AT do not apply automatically to RXSOL.
RXSOL BOILPLEX AT Hardness Control Sludge Conditioner most commonly used in low and medium pressure boilers, to keep BOILER WATER CLEAR and Sludge free.
Technical Specifications
|
Parameter |
RXSOL Specification / Description |
|---|---|
|
Appearance |
Clear liquid |
|
Specific Gravity at 25°C |
1.056 (published RXSOL value) |
|
Chemical Base |
Phosphate and synthetic polymer blend |
|
Physical Form |
Liquid |
|
Water Compatibility |
Intended for aqueous dosing |
|
Primary Function |
Hardness, scale and sludge control |
|
Secondary Function |
Alkalinity and corrosion management |
|
Standard Packing |
25 L |
The appearance and specific gravity are taken from the published RXSOL product listing. Other quantitative properties, including pH, phosphate concentration and active polymer content, require batch-specific confirmation.
RXSOL – Manufacturer & Supplier
Boiler Water Treatment Mechanism
1. Hardness Control
Phosphate compounds react with residual calcium hardness to form less adherent precipitates that can be conditioned and removed through blowdown.
2. Polymer Dispersion
Synthetic polymers help disperse suspended particles, iron oxides and hardness precipitates, reducing deposit accumulation on boiler heating surfaces.
3. Scale Prevention
The combination of phosphate treatment and polymeric deposit control helps limit hard scale formation and associated heat-transfer losses.
4. Alkalinity Management
Alkalinity-control ingredients maintain suitable boiler water conditions, reducing the risk of certain forms of internal corrosion.
5. Condensate Protection
Where the verified formulation includes an appropriate volatile neutralizing amine, it may also support condensate system pH control.
Recommended Companion Treatment
RXSOL BOILPLEX AT should be used with an appropriate oxygen scavenger where required by the boiler treatment program.
Suitable treatment technologies may include DEHA-based, catalyzed sulphite or other approved oxygen-scavenging systems, selected according to boiler pressure, steam application and water quality.
BOILPLEX AT should not be assumed to remove dissolved oxygen on its own.
Product Details
|
Field |
Details |
|---|---|
|
RXSOL Product Title |
BOILPLEX AT Boiler Water Treatment Chemical – RXSOL |
|
RXSOL Description |
RXSOL BOILPLEX AT RXSOL-40-5027-025 is a phosphate-polymer boiler treatment for scale prevention, sludge conditioning and marine boiler maintenance. |
|
RXSOL Product |
|
|
Boiler Water Focus |
BOILPLEX AT Boiler Water Treatment |
|
Product |
Phosphate Polymer Boiler Treatment, Marine Boiler Scale Inhibitor, Boiler Sludge Conditioner, Boiler Water Treatment Supplier |
|
Product |
RXSOL BOILPLEX AT phosphate polymer boiler water treatment chemical 25 litre |
RXSOL BOILPLEX AT should be presented as an independently branded product for similar applications.
RXSOL BOILPLEX AT Manufacturer, Supplier and Exporter
RXSOL supplies boiler water treatment chemicals for marine vessels, shipyards, industrial boiler operators and water treatment service companies.
India: Mumbai, Kolkata, Chennai, Ennore, Kandla, Mundra, Visakhapatnam and other industrial locations.
UAE: Dubai, Fujairah, Sharjah and Abu Dhabi.
Oman: Muscat, Sohar, Salalah and Duqm.
For product specifications, bulk supply, SDS, COA and quotations, contact the RXSOL sales team.
RXSOL BOILPLEX AT – Product Details
Phosphate and synthetic polymer Based Boiler water treatment chemicals to control sludge for low and medium pressure boilers RXSOL BOILPLEX AT Hardness Control manufacturer ans supplier in Mumbai, Gandhidham Surat Gujrat, Chennai, Ennore, Visakhapatnam VIZAG Andhra Pradesh, Kolkata, Haldia, Paradip, Fujairah, Sharjah, Ajman, Abudhabi, Muscat Oman, Canada BE, Nairobi Mombasa, Kenya, Jinja Kampala, Uganda
